Lighting Simplified.

Emergency + egress lighting / product research

Start with the emergency requirement, not the fixture shape.

Emergency lighting selection depends on the project’s egress design, emergency-power method, required performance, environment, testing requirements, and the governing construction documents. FindLEDs can help research products and manufacturer options; the project designer, code professional, and authority having jurisdiction remain responsible for final compliance decisions.

Egress condition

Identify the path, room, stair, exit, or exterior condition the emergency equipment is intended to serve.

Emergency power method

Unit equipment, combination exit/emergency unit, integral fixture backup, or a larger inverter/central system can lead to very different products.

Required operation

Confirm the project’s required emergency duration, output, transfer behavior, and normal/emergency operating mode from the governing documents.

Testing + maintenance

Self-test/self-diagnostic capability, test access, indicators, battery serviceability, and maintenance procedures can matter as much as fixture appearance.

Product paths

Different emergency strategies produce different product families.

A product that is appropriate for one emergency-power strategy may be completely wrong for another even if it looks similar.

Emergency unit equipment

Dedicated battery-backed heads or compact emergency fixtures

Corridors, rooms, egress routes, stair/support areas, and projects using separate emergency units.

Exit / combination units

Exit identification with optional integrated emergency heads

Projects where exit marking and emergency illumination can be served from one listed assembly.

Integral emergency backup

Emergency driver or battery option within a normal luminaire family

Projects that need selected normal fixtures to continue operating during loss of normal power.

Inverter / central systems

Backup power supplied to connected lighting circuits or luminaires

Larger projects where emergency operation is coordinated at the system level rather than fixture by fixture.

From the live catalog

Current emergency and exit families

Research current manufacturer families in the FindLEDs catalog.

NC-BUGRC01 Dual Head LED Emergency Light Remote Capable
NCL Lighting

NC-BUGRC01 Dual Head LED Emergency Light Remote Capable

2 × 1.2W LED headsW
Open in catalog
NC-BUGWL01 LED Emergency Light
NCL Lighting

NC-BUGWL01 LED Emergency Light

2 × 1.2W LED headsW
Open in catalog
NC-EXCM01-RG Combo LED EXIT Emergency Light
NCL Lighting

NC-EXCM01-RG Combo LED EXIT Emergency Light

2.4W emergency lightingW
Open in catalog
Comparison checklist

Compare the requirement that must survive the outage.

Emergency operating method
Input voltage and normal operating mode
Emergency output / lumen performance
Project-required runtime
Self-test / diagnostic features
Mounting and egress location
Environmental / wet-location rating
Battery and service requirements
Listings and project specifications
Warranty and manufacturer documentation

Product research is not the final code determination.

Emergency and egress requirements vary with occupancy, building design, adopted codes, project specifications, and local enforcement. Use manufacturer documentation and the project’s design criteria to evaluate products, then confirm the final layout, equipment, installation, and testing requirements with the responsible design professional and authority having jurisdiction.